Introduction
The M230T Ethernet Remote I/O Module is an industrial class, isolated designed, exceptionally reliable and very precise data acquisition module, embedded 32-Bit High Performance Microprocessor MCU, Integrated 1 Industrial 10/100M adaptive Ethernet module inside. It provides multi I/O, supports standard Modbus TCP, can be intergraded into SCADA, OPC server, MQTT protocol, and other automation systems. It is designed for working in harsh industrial environments and is widely used in a variety of industrial automation, security monitoring system, automatically measurement and control system.
The M230 Industrial Remote I/O module provides a RS485 interface, through the RS485 bus, it can cascade Modbus RTU I/O devices or Modbus RTU meters, e.g.: a variety of digital input or digital outputs, analog inputs or outputs, thermal resistance IO module combination. At the same time, the Ethernet Remote I/O module has register mapping function, the cascade Modbus RTU I/O data are automatically collected to the mapping memory area, the Modbus TCP Client query without waiting then can get a quick response to meet the industrial timing requirements.
Features
1. Embedded 32-Bit High Performance Microprocessor MCU, built-in watchdog.
2. Wide range power supply 12 ~ 36VDC with over voltage and phase-reversal protection.
3. Management and configuration via LAN connection configuration software for effortless operation and maintenance.
4. Integrated 10/100M adaptive Ethernet module, supports Modbus TCP protocol.
5. 4 isolated analog input, 12-bit resolution, supports 0~20mA,4~20mA,0-5VDC, 0-10VDC.
6. High sampling frequency and special filtering strategy to ensure reliability.
7. 1 RS485 Serial port, supports Modbus RTU/ASCII Master, can extend I/O modules.
8. Supports register mapping function and extends I/O inquiry strategy.
9.Provides 1 channel 12~36VDC power source output for external device, saving wiring cost.
10.LED instructions work status, with reset button to reset, easy on-site installation and commissioning.
11.Using metal shell, protection class IP30. Metal shell and system security isolation, especially suitable for industrial applications in the field.
12.Small size, L105 mm (about 4.13 in) * W88mm (about 3.46 in) * H30mm (about 1.18 in), compatible wall installation and DIN35mm (about 1.38 in) industrial rail installation.
Specifications
Analog Input
Type |
Differential Input |
Resolution |
12 bits |
I/O Mode |
Voltage/Current (jumper selectable) |
Input Range |
0 to 10 VDC, 0 to 20 mA, 4 to 20 mA |
Counter Frequency |
±0.1% FSR @ 25º C ±0.3% FSR @ -10 and 60º C ±0.5% FSR @ -40 and 75º C |
Sampling Frequency |
20Hz |
Built-In Resistor for Current Input | 162 ohms |
Isolation |
Electrical Isolation |
Working Power Requirements
Input Voltage |
12 to 36 VDC, Peak Voltage; +40VDC Power Consumption: Less Than 3W |
Input Current | 139mA @24VDC |
Power Output
Output Voltage |
12 to 36 VDC |
Output Current | 139mA @ 24 VDC |
LAN
Ethernet | 10/100Mbps RJ45 ports |
Protection | 15KV ESD Protection |
Protocols | Modbus TCP, TCP/IP |
Max TCP Connection | 5 |
Serial Port
RS485 | MODBUS- RTU Protocol, Modbus-ASCII Protocol |
Protection | 15KV ESD Protection |
Modbus Slave Address | 1-255 |
Baud Rate | 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 128000Bps |
Mapping Registers | Bit Type: 300 Registers, 16-Bit Type: 300 Registers |
Physical Characteristics
Wiring | I/O Cable Max. 14AWG |
Dimensions | 105mm x 88mm x 30mm |
Weight | Under 205grams |
Mounting | DIN Rail or Wall |
Environmental Limits
Operating Temperature |
Standard Model: -10 to 60°C (14 to 140°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F) |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
Altitude | Up to 3000m |
Downloads
M230T Data Sheet Download
M230T User Manual
Applications
Typical applications:
- BTS Monitoring.
- Security Alarm System applications.
- Supervision and monitoring alarm systems.
- Automatic monitoring system.
- Vending Machines security protection.
- Pumping Stations, Tanks, Oil or Water levels.
- Buildings and Real Estate.
- Weather Stations.
- River Monitoring and Flood Control.
- Oil and gas pipelines.
- Corrosion protection
- Temperatures, water leakage applications.
- Wellheads, boat, vehicle.
- Energy saving, streetlights control system.
- Valve controls.
- Transformer stations.
- Unmanned machine rooms.
- Control room application.
- Automation System, M2M.
- Access Control System.
- PLC Gateway, PLC Remote Monitoring.
![M230T Analog Input Module - IOT USA](http://www.iotusa.com/cdn/shop/products/M230-01.jpg?v=1657210409&width=1445)
![M230T Analog Input Module - IOT USA](http://www.iotusa.com/cdn/shop/products/M230-02.jpg?v=1657210409&width=1445)
![M230T Analog Input Module - IOT USA](http://www.iotusa.com/cdn/shop/products/M230-03.jpg?v=1657210409&width=1445)
![M230T Analog Input Module - IOT USA](http://www.iotusa.com/cdn/shop/products/M230-04.jpg?v=1657210409&width=1445)
![M230T Analog Input Module - IOT USA](http://www.iotusa.com/cdn/shop/products/M230-05.jpg?v=1657210409&width=1445)
![M230T Analog Input Module - IOT USA](http://www.iotusa.com/cdn/shop/products/M230Datasheet-01.jpg?v=1657210409&width=1445)
![M230T Analog Input Module - IOT USA](http://www.iotusa.com/cdn/shop/products/M230Datasheet-02.jpg?v=1657210409&width=1445)